, Commission communication under Directive 89/336/EEC OJ C 246 of 2005-10-05. This list replaces all the previous lists published in the Official Journal of the European Union.
Please note that four erroneous ^dates of cessation of presumption of conformity of the superseded standard ̄ were inserted in the Official journal C 246 of 5 October 2005 , and that an Official Journal corrigendum is being prepared. The corresponding dates in the table below have to be corrected as follows:
1. The new standard EN 300 386 V.1.2.1 (second column of the table below), will supersede EN 301 386-2 V.1.1.3
on 31-08-2007 (instead of 31-08-2005 in the fourth column)
2. The new standard EN 300 386 V.1.3.1 (second column of the table below), will supersede EN 301 386-2 V.1.2.1
on 31-08-2007 (instead of 31-08-2005 in the fourth column)
3. The new standard EN 300 386 V.1.3.2 (second column of the table below), will supersede EN 301 386-2 V.1.2.1
on 31-08-2007 (instead of 31-08-2005 in the fourth column)
4. The new standard EN 300 386-2 V1.1.3 (second column of the table below) does not supersede any standard (third column correctly empty already)
and therefore no cessation date should be mentioned in the fourth column (instead of 31-08-2005 )
, in their conformity assessment, to continue using EN 300 386 V.1.1.3 until the correct date of 31-08-2007
, in their technical file, to continue referencing this standard EN 300 386 V.1.1.3 until the correct date of 31-08-2007 when they use and establish this technical file before this date.
Summary list of titles and references of harmonised standards under Directive 89/336/EEC on EMC
The information contained in the summary list is a compilation of the references of standards which have been published in the Official Journal of the European Union. Although the lists are updated regularly, they may not be complete and they do not have any legal validity; only publication in the Official Journal produces legal affect.
European Standardisation Organisation |
Reference and title of the standard (and reference document) |
Reference of the superseded standard |
Date of cessation of presumption of conformity of the superseded standard Note 1 |
|
|
|
|
CENELEC |
EN 50065-1:2001
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz --
Part 1: General requirements, frequency bands and electromagnetic disturbances |
EN 50065-1:1991
+A1:1992
+A2:1995
+A3:1996
Note 2.1
|
Date expired (01.04.2003)
|
|
|
|
|
CENELEC |
EN 50065-2-1:2003
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz --
Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.2004)
|
|
|
|
|
CENELEC |
EN 50065-2-2:2003
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz --
Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.2004)
|
|
|
|
|
CENELEC |
EN 50065-2-3:2003
Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz --
Part 2-3: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.08.2004)
|
|
|
|
|
CENELEC |
EN 50083-2:2001
Cable networks for television signals, sound signals and interactive services --
Part 2: Electromagnetic compatibility for equipment |
EN 50083-2:1995
+A1:1997
Note 2.1
|
Date expired (01.01.2004)
|
|
|
|
|
CENELEC |
EN 50090-2-2:1996
Home and Building Electronic Systems (HBES) --
Part 2-2: System overview - General technical requirements |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.1999)
|
|
|
|
|
CENELEC |
EN 50091-2:1995
Uninterruptible power systems (UPS) --
Part 2: EMC requirements |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.03.1999)
|
|
|
|
|
CENELEC |
EN 50130-4:1995
Alarm systems --
Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.01.2001)
|
|
Amendment A1:1998 to EN 50130-4:1995 |
Note 3 |
Date expired (01.01.2001) |
|
Amendment A2:2003 to EN 50130-4:1995 |
Note 3 |
01.09.2007 |
|
|
|
|
CENELEC |
EN 50148:1995
Electronic taximeters |
Relevant generic standard(s)
Note 2.3
|
Date expired (15.12.1995)
|
|
|
|
|
CENELEC |
EN 50199:1995
Electromagnetic compatibility (EMC) - Product standard for arc welding equipment |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.07.1996)
|
|
|
|
|
CENELEC |
EN 50240:2004
Electromagnetic compatibility (EMC) - Product standard for resistance welding equipment |
Relevant generic standard(s)
Note 2.3
|
01.04.2007
|
|
|
|
|
CENELEC |
EN 50263:1999
Electromagnetic compatibility (EMC) - Product standard for measuring relays and protection equipment |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.08.2002)
|
|
|
|
|
CENELEC |
EN 50270:1999
Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.2001)
|
|
|
|
|
CENELEC |
EN 50293:2000
Electromagnetic compatibility - Road traffic signal systems - Product standard |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.04.2003)
|
|
|
|
|
CENELEC |
EN 50295:1999
Low-voltage switchgear and controlgear - Controller and device interface systems - Actuator Sensor interface (AS-i) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.12.1999)
|
|
|
|
|
CENELEC |
EN 50370-1:2005
Electromagnetic compatibility (EMC) - Product family standard for machine tools --
Part 1: Emission |
Relevant generic standard(s)
Note 2.3
|
01.02.2008
|
|
|
|
|
CENELEC |
EN 50370-2:2003
Electromagnetic compatibility (EMC) - Product family standard for machine tools --
Part 2: Immunity |
Relevant generic standard(s)
Note 2.3
|
01.11.2005
|
|
|
|
|
CENELEC |
EN 55011:1998
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement
(CISPR 11:1997 (Modified)) |
EN 55011:1991
+A1:1997
+A2:1996
Note 2.1
|
Date expired (01.01.2001)
|
|
Amendment A1:1999 to EN 55011:1998
(CISPR 11:1997/A1:1999) |
Note 3 |
Date expired (01.08.2002) |
|
Amendment A2:2002 to EN 55011:1998
(CISPR 11:1997/A2:2002) |
Note 3 |
01.10.2005 |
|
|
|
|
CENELEC |
EN 55012:2002
Vehicles, boats and internal combustion engine driven devices - Radio disturbance characteristics - Limits and methods of measurement for the protection of receivers except those installed in the vehicle/boat/device itself or in adjacent vehicles/boats/devices
(CISPR 12:2001)
Note 8 |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.02.2005)
|
|
Amendment A1:2005 to EN 55012:2002
(CISPR 12:2001/A1:2005) |
Note 3 |
01.03.2008 |
|
|
|
|
CENELEC |
EN 55013:2001
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
(CISPR 13:2001 (Modified)) |
EN 55013:1990
+A12:1994
+A13:1996
+A14:1999
Note 2.1
|
Date expired (01.09.2004)
|
|
Amendment A1:2003 to EN 55013:2001
(CISPR 13:2001/A1:2003) |
Note 3 |
01.04.2006 |
|
|
|
|
CENELEC |
EN 55014-1:2000
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus --
Part 1: Emission
(CISPR 14-1:2000) |
EN 55014-1:1993
+A1:1997
+A2:1999
Note 2.1
|
Date expired (01.08.2003)
|
|
Amendment A1:2001 to EN 55014-1:2000
(CISPR 14-1:2000/A1:2001) |
Note 3 |
Date expired (01.10.2004) |
|
Amendment A2:2002 to EN 55014-1:2000
(CISPR 14-1:2000/A2:2002) |
Note 3 |
01.10.2005 |
|
|
|
|
CENELEC |
EN 55014-2:1997
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus --
Part 2: Immunity - Product family standard
(CISPR 14-2:1997) |
EN 55104:1995
Note 2.1
|
Date expired (01.01.2001)
|
|
Amendment A1:2001 to EN 55014-2:1997
(CISPR 14-2:1997/A1:2001) |
Note 3 |
Date expired (01.12.2004) |
|
|
|
|
CENELEC |
EN 55015:2000
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(CISPR 15:2000) |
EN 55015:1996
+A1:1997
+A2:1999
Note 2.1
|
Date expired (01.08.2003)
|
|
Amendment A1:2001 to EN 55015:2000
(CISPR 15:2000/A1:2001) |
Note 3 |
Date expired (01.12.2004) |
|
Amendment A2:2002 to EN 55015:2000
(CISPR 15:2000/A2:2002) |
Note 3 |
01.10.2005 |
|
|
|
|
CENELEC |
EN 55020:1994
Electromagnetic immunity of broadcast receivers and associated equipment |
EN 55020:1988
Note 2.1
|
Date expired (31.12.1998)
|
|
Amendment A11:1996 to EN 55020:1994 |
Note 3 |
Date expired (01.06.1999) |
|
Amendment A13:1999 to EN 55020:1994 |
Note 3 |
Date expired (01.08.2001) |
|
Amendment A14:1999 to EN 55020:1994 |
Note 3 |
Date expired (01.08.2001) |
|
Amendment A12:1999 to EN 55020:1994 |
Note 3 |
Date expired (01.08.2002) |
|
|
|
|
CENELEC |
EN 55020:2002
Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement
(CISPR 20:2002) |
EN 55020:1994
and its amendments
Note 2.1
|
01.12.2005
|
|
Amendment A1:2003 to EN 55020:2002
(CISPR 20:2002/A1:2002) |
Note 3 |
01.12.2005 |
|
Amendment A2:2005 to EN 55020:2002
(CISPR 20:2002/A2:2004) |
Note 3 |
01.02.2008 |
|
|
|
|
CENELEC |
EN 55022:1994
Limits and methods of measurement of radio disturbance characteristics of information technology equipment
(CISPR 22:1993) |
EN 55022:1987
Note 2.1
|
Date expired (31.12.1998)
|
|
Amendment A1:1995 to EN 55022:1994
(CISPR 22:1993/A1:1995) |
Note 3 |
Date expired (31.12.1998) |
|
Amendment A2:1997 to EN 55022:1994
(CISPR 22:1993/A2:1996 (Modified)) |
Note 3 |
Date expired (31.12.1998) |
|
|
|
|
CENELEC |
EN 55022:1998
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
(CISPR 22:1997 (Modified)) |
EN 55022:1994
and its amendments
Note 2.1
|
01.08.2007
|
|
Amendment A1:2000 to EN 55022:1998
(CISPR 22:1997/A1:2000) |
Note 3 |
Date expired (01.08.2005) |
|
Amendment A2:2003 to EN 55022:1998
(CISPR 22:1997/A2:2002) |
Note 3 |
01.12.2005 |
|
|
|
|
CENELEC |
EN 55024:1998
Information technology equipment - Immunity characteristics - Limits and methods of measurement
(CISPR 24:1997 (Modified)) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.07.2001)
|
|
Amendment A1:2001 to EN 55024:1998
(CISPR 24:1997/A1:2001) |
Note 3 |
Date expired (01.10.2004) |
|
Amendment A2:2003 to EN 55024:1998
(CISPR 24:1997/A2:2002) |
Note 3 |
01.12.2005 |
|
|
|
|
CENELEC |
EN 55103-1:1996
Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use --
Part 1: Emission |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.09.1999)
|
|
|
|
|
CENELEC |
EN 55103-2:1996
Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use --
Part 2: Immunity |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.09.1999)
|
|
|
|
|
CENELEC |
EN 60034-1:1998
Rotating electrical machines --
Part 1: Rating and performance
(IEC 60034-1:1996 (Modified)) |
-
|
-
|
|
Amendment A11:2002 to EN 60034-1:1998 |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.07.2005) |
|
|
|
|
CENELEC |
EN 60204-31:1998
Safety of machinery - Electrical equipment of machines --
Part 31: Particular safety and EMC requirements for sewing machines, units and systems
(IEC 60204-31:1996 (Modified)) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.06.2002)
|
|
|
|
|
CENELEC |
EN 60439-1:1999
Low-voltage switchgear and controlgear assemblies --
Part 1: Type-tested and partially type-tested assemblies
(IEC 60439-1:1999) |
EN 60439-1:1994
+A11:1996
Note 2.1
|
Date expired (01.08.2002)
|
|
|
|
|
CENELEC |
EN 60521:1995
Class 0,5, 1 and 2 alternating-current watt-hour meters
(IEC 60521:1988) |
Relevant generic standard(s)
Note 2.3
|
Date expired (15.07.1995)
|
|
|
|
|
CENELEC |
EN 60669-2-1:1996
Switches for household and similar fixed-electrical installations --
Part 2: Particular requirements --
Section 1: Electronic switches
(IEC 60669-2-1:1994 + A1:1994 + A2:1995 (Modified)) |
-
|
-
|
|
Amendment A11:1997 to EN 60669-2-1:1996 |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.06.1999) |
|
|
|
|
CENELEC |
EN 60669-2-1:2000
Switches for household and similar fixed electrical installations --
Part 2-1: Particular requirements - Electronic switches
(IEC 60669-2-1:1996 + A1:1997 (Modified)) |
EN 60669-2-1:1996
and its amendment
Note 2.1
|
01.10.2005
|
|
Amendment A2:2001 to EN 60669-2-1:2000
(IEC 60669-2-1:1996/A2:1999 (Modified)) |
Note 3 |
01.10.2005 |
|
|
|
|
CENELEC |
EN 60669-2-2:1997
Switches for household and similar fixed electrical installations --
Part 2: Particular requirements --
Section 2: Electromagnetic remote-control switches (RCS)
(IEC 60669-2-2:1996) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.06.1999)
|
|
|
|
|
CENELEC |
EN 60669-2-3:1997
Switches for household and similar fixed electrical installations --
Part 2-3: Particular requirements - Time-delay switches (TDS)
(IEC 60669-2-3:1997) |
EN 60669-2-3:1996
Note 2.1
|
Date expired (01.06.1999)
|
|
|
|
|
CENELEC |
EN 60687:1992
Alternating current static watt-hour meters for active energy (classes 0,2 S and 0,5 S)
(IEC 60687:1992) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.06.1993)
|
|
EN 60730-1:1995
and its amendments
Note 2.3
|
Date expired (15.12.2000)
|
|
|
|
|
CENELEC |
EN 60730-2-5:2002
Automatic electrical controls for household and similar use --
Part 2-5: Particular requirements for automatic electrical burner control systems
(IEC 60730-2-5:2000 (Modified))
Note 10 |
EN 60730-2-5:1995
Note 2.1
|
01.12.2008
|
|
Amendment A1:2004 to EN 60730-2-5:2002
(IEC 60730-2-5:2000/A1:2004 (Modified)) |
Note 3 |
01.12.2008 |
|
Amendment A11:2005 to EN 60730-2-5:2002 |
Note 3 |
01.12.2008 |
|
|
|
|
CENELEC |
EN 60730-2-6:1995
Automatic electrical controls for household and similar use --
Part 2: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements
(IEC 60730-2-6:1991 (Modified)) |
-
|
-
|
|
Amendment A1:1997 to EN 60730-2-6:1995
(IEC 60730-2-6:1991/A1:1994 (Modified)) |
Note 3 |
Date expired (15.12.2003) |
|
|
|
|
CENELEC |
EN 60730-2-7:1991
Automatic electrical controls for household and similar use --
Part 2: Particular requirements for timers and time switches
(IEC 60730-2-7:1990 (Modified)) |
-
|
-
|
|
Amendment A1:1997 to EN 60730-2-7:1991
(IEC 60730-2-7:1990/A1:1994 (Modified)) |
Note 3 |
Date expired (01.01.2004) |
|
|
|
|
CENELEC |
EN 60730-2-8:1995
Automatic electrical controls for household and similar use --
Part 2: Particular requirements for electrically operated water valves, including mechanical requirements
(IEC 60730-2-8:1992 (Modified)) |
-
|
-
|
|
Amendment A1:1997 to EN 60730-2-8:1995
(IEC 60730-2-8:1992/A1:1994 (Modified)) |
Note 3 |
Date expired (01.01.2004) |
|
Amendment A2:1997 to EN 60730-2-8:1995
(IEC 60730-2-8:1992/A2:1997) |
Note 3 |
Date expired (01.01.2004) |
|
|
|
|
CENELEC |
EN 60730-2-8:2002
Automatic electrical controls for household and similar use --
Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements
(IEC 60730-2-8:2000 (Modified)) |
EN 60730-2-8:1995
and its amendments
Note 2.1
|
01.12.2008
|
|
Amendment A1:2003 to EN 60730-2-8:2002
(IEC 60730-2-8:2000/A1:2002 (Modified)) |
Note 3 |
01.12.2008 |
|
|
|
|
CENELEC |
EN 60730-2-9:1995
Automatic electrical controls for household and similar use --
Part 2: Particular requirements for temperature sensing controls
(IEC 60730-2-9:1992 (Modified)) |
-
|
-
|
|
Amendment A1:1996 to EN 60730-2-9:1995
(IEC 60730-2-9:1992/A1:1994 (Modified)) |
Note 3 |
Date expired (01.01.2004) |
|
Amendment A2:1997 to EN 60730-2-9:1995
(IEC 60730-2-9:1992/A2:1994 (Modified)) |
Note 3 |
Date expired (01.01.2004) |
|
|
|
|
CENELEC |
EN 60730-2-9:2002
Automatic electrical controls for household and similar use --
Part 2-9: Particular requirements for temperature sensing controls
(IEC 60730-2-9:2000 (Modified)) |
EN 60730-2-9:1995
and its amendments
Note 2.1
|
01.12.2008
|
|
Amendment A2:2005 to EN 60730-2-9:2002
(IEC 60730-2-9:2000/A2:2004 (Modified)) |
Note 3 |
01.12.2007 |
|
Amendment A1:2003 to EN 60730-2-9:2002
(IEC 60730-2-9:2000/A1:2002 (Modified)) |
Note 3 |
01.12.2008 |
|
|
|
|
CENELEC |
EN 60730-2-11:1993
Automatic electrical controls for household and similar use --
Part 2-11: Particular requirements for energy regulators
(IEC 60730-2-11:1993) |
-
|
-
|
|
Amendment A1:1997 to EN 60730-2-11:1993
(IEC 60730-2-11:1993/A1:1994 (Modified)) |
Note 3 |
Date expired (01.07.2000) |
|
Amendment A11:2005 to EN 60730-2-11:1993 |
Note 3 |
01.03.2009 |
|
|
|
|
CENELEC |
EN 60730-2-13:1998
Automatic electrical controls for household and similar use --
Part 2-13: Particular requirements for humidity sensing controls
(IEC 60730-2-13:1995 (Modified)) |
EN 60730-1:1995
and its amendments
Note 2.3
|
Date expired (01.08.2001)
|
|
Amendment A11:2005 to EN 60730-2-13:1998 |
Note 3 |
01.02.2009 |
|
|
|
|
CENELEC |
EN 60730-2-14:1997
Automatic electrical controls for household and similar use --
Part 2-14: Particular requirements for electric actuators
(IEC 60730-2-14:1995 (Modified)) |
EN 60730-1:1995
and its amendments
Note 2.3
|
Date expired (01.06.2004)
|
|
Amendment A1:2001 to EN 60730-2-14:1997
(IEC 60730-2-14:1995/A1:2001) |
Note 3 |
01.07.2008 |
|
|
|
|
CENELEC |
EN 60730-2-18:1999
Automatic electrical controls for household and similar use --
Part 2-18: Particular requirements for automatic electrical water and air flow sensing controls, including mechanical requirements
(IEC 60730-2-18:1997 (Modified)) |
EN 60730-1:1995
and its amendments
Note 2.3
|
Date expired (01.04.2002)
|
|
|
|
|
CENELEC |
EN 60870-2-1:1996
Telecontrol equipment and systems --
Part 2: Operating conditions --
Section 1: Power supply and electromagnetic compatibility
(IEC 60870-2-1:1995) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.09.1996)
|
|
|
|
|
CENELEC |
EN 60945:1997
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
(IEC 60945:1996) |
EN 60945:1995
Note 2.1
|
Date expired (01.09.1997)
|
|
|
|
|
CENELEC |
EN 60945:2002
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
(IEC 60945:2002) |
EN 60945:1997
Note 2.1
|
01.10.2005
|
|
|
|
|
CENELEC |
EN 60947-1:1999
Low-voltage switchgear and controlgear --
Part 1: General rules
(IEC 60947-1:1999 (Modified))
Note 6 |
EN 60947-1:1997
Note 2.1
|
Date expired (01.11.2001)
|
|
Amendment A2:2001 to EN 60947-1:1999
(IEC 60947-1:1999/A2:2001) |
Note 3 |
Date expired (01.12.2004) |
|
|
|
|
CENELEC |
EN 60947-1:2004
Low-voltage switchgear and controlgear --
Part 1: General rules
(IEC 60947-1:2004)
Note 6 |
EN 60947-1:1999
and its amendment
Note 2.1
|
01.04.2007
|
|
|
|
|
CENELEC |
EN 60947-2:1996
Low-voltage switchgear and controlgear --
Part 2: Circuit-breakers
(IEC 60947-2:1995) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.1997)
|
|
Amendment A1:1997 to EN 60947-2:1996
(IEC 60947-2:1995/A1:1997) |
EN 60947-2:1996/A11:1997
Note 3 |
Date expired (01.08.1998) |
|
Amendment A2:2001 to EN 60947-2:1996
(IEC 60947-2:1995/A2:2001) |
Note 3 |
Date expired (01.07.2004) |
|
|
|
|
CENELEC |
EN 60947-2:2003
Low-voltage switchgear and controlgear --
Part 2: Circuit-breakers
(IEC 60947-2:2003) |
EN 60947-2:1996
and its amendments
Note 2.1
|
01.06.2006
|
|
|
|
|
CENELEC |
EN 60947-3:1999
Low-voltage switchgear and controlgear --
Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
(IEC 60947-3:1999) |
EN 60947-3:1992
+A1:1995
Note 2.1
|
Date expired (01.01.2002)
|
|
Amendment A1:2001 to EN 60947-3:1999
(IEC 60947-3:1999/A1:2001) |
Note 3 |
Date expired (01.03.2004) |
|
|
|
|
CENELEC |
EN 60947-4-1:1992
Low-voltage switchgear and controlgear --
Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
(IEC 60947-4-1:1990) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.1997)
|
|
Amendment A2:1997 to EN 60947-4-1:1992
(IEC 60947-4-1:1990/A2:1996) |
Note 3 |
Date expired (01.10.1997) |
|
|
|
|
CENELEC |
EN 60947-4-1:2001
Low-voltage switchgear and controlgear --
Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
(IEC 60947-4-1:2000) |
-
|
-
|
|
Amendment A1:2002 to EN 60947-4-1:2001
(IEC 60947-4-1:2000/A1:2002) |
EN 60947-4-1:1992
and its amendments
Note 2.1 |
01.10.2005 |
|
|
|
|
CENELEC |
EN 60947-4-2:2000
Low-voltage switchgear and controlgear --
Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
(IEC 60947-4-2:1999) |
EN 60947-4-2:1996
+A2:1998
Note 2.1
|
Date expired (01.12.2002)
|
|
Amendment A1:2002 to EN 60947-4-2:2000
(IEC 60947-4-2:1999/A1:2001) |
Note 3 |
Date expired (01.03.2005) |
|
|
|
|
CENELEC |
EN 60947-4-3:2000
Low-voltage switchgear and controlgear --
Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
(IEC 60947-4-3:1999) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.12.2002)
|
|
|
|
|
CENELEC |
EN 60947-5-1:1997
Low-voltage switchgear and controlgear --
Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices
(IEC 60947-5-1:1997) |
-
|
-
|
|
Amendment A12:1999 to EN 60947-5-1:1997 |
EN 60947-5-1:1991
+A12:1997
Note 2.1 |
Date expired (01.10.2002) |
|
|
|
|
CENELEC |
EN 60947-5-1:2004
Low-voltage switchgear and controlgear --
Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices
(IEC 60947-5-1:2003) |
EN 60947-5-1:1997
and its amendment
Note 2.1
|
01.05.2007
|
|
|
|
|
CENELEC |
EN 60947-5-2:1998
Low-voltage switchgear and controlgear --
Part 5-2: Control circuit devices and switching elements - Proximity switches
(IEC 60947-5-2:1997 (Modified)) |
EN 60947-5-2:1997
Note 2.1
|
Date expired (01.10.2001)
|
|
Amendment A2:2004 to EN 60947-5-2:1998
(IEC 60947-5-2:1997/A2:2003) |
Note 3 |
01.02.2007 |
|
|
|
|
CENELEC |
EN 60947-5-3:1999
Low-voltage switchgear and controlgear --
Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDF)
(IEC 60947-5-3:1999) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.05.2002)
|
|
Amendment A1:2005 to EN 60947-5-3:1999
(IEC 60947-5-3:1999/A1:2005) |
Note 3 |
01.03.2008 |
|
|
|
|
CENELEC |
EN 60947-5-6:2000
Low-voltage switchgear and controlgear --
Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR)
(IEC 60947-5-6:1999) |
EN 50227:1997
Note 2.1
|
Date expired (01.01.2003)
|
|
|
|
|
CENELEC |
EN 60947-5-7:2003
Low-voltage switchgear and controlgear --
Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output
(IEC 60947-5-7:2003) |
Relevant generic standard(s)
Note 2.3
|
01.09.2006
|
|
|
|
|
CENELEC |
EN 60947-6-1:1991
Low-voltage switchgear and controlgear --
Part 6-1: Multiple function equipment - Automatic transfer switching equipment
(IEC 60947-6-1:1989) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.1997)
|
|
Amendment A2:1997 to EN 60947-6-1:1991
(IEC 60947-6-1:1989/A2:1997) |
EN 60947-6-1:1991/A11:1997
Note 3 |
Date expired (01.07.1998) |
|
|
|
|
CENELEC |
EN 60947-6-2:1993
Low-voltage switchgear and controlgear --
Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS)
(IEC 60947-6-2:1992) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.10.1997)
|
|
Amendment A1:1997 to EN 60947-6-2:1993
(IEC 60947-6-2:1992/A1:1997) |
EN 60947-6-2:1993/A11:1997
Note 3 |
Date expired (01.07.1998) |
|
|
|
|
CENELEC |
EN 60947-6-2:2003
Low-voltage switchgear and controlgear --
Part 6-2: Multiple function equipment - Control and protective switching devices (or equipment) (CPS)
(IEC 60947-6-2:2002) |
EN 60947-6-2:1993
and its amendment
Note 2.1
|
01.09.2005
|
|
|
|
|
CENELEC |
EN 60947-8:2003
Low-voltage switchgear and controlgear --
Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines
(IEC 60947-8:2003) |
Relevant generic standard(s)
Note 2.3
|
01.07.2006
|
|
|
|
|
CENELEC |
EN 60974-10:2003
Arc welding equipment --
Part 10: Electromagnetic compatibility (EMC) requirements
(IEC 60974-10:2002 (Modified)) |
EN 50199:1995
Note 2.1
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 61000-3-2:2000
Electromagnetic compatibility (EMC) --
Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)
(IEC 61000-3-2:2000 (Modified)) |
EN 61000-3-2:1995
+A1:1998
+A2:1998
+A14:2000
Note 2.1
|
Date expired (01.01.2004)
|
|
Amendment A2:2005 to EN 61000-3-2:2000
(IEC 61000-3-2:2000/A1:2001 + A2:2004) |
Note 3 |
01.01.2008 |
|
|
|
|
CENELEC |
EN 61000-3-3:1995
Electromagnetic compatibility (EMC) --
Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection
(IEC 61000-3-3:1994) |
EN 60555-3:1987
+A1:1991
Note 2.2
|
Date expired (01.01.2001)
|
|
Amendment A1:2001 to EN 61000-3-3:1995
(IEC 61000-3-3:1994/A1:2001) |
Note 3 |
Date expired (01.05.2004) |
|
|
|
|
CENELEC |
EN 61000-3-11:2000
Electromagnetic compatibility (EMC) --
Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection
(IEC 61000-3-11:2000) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.11.2003)
|
|
|
|
|
CENELEC |
EN 61000-3-12:2005
Electromagnetic compatibility (EMC) --
Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <= 75 A per phase
(IEC 61000-3-12:2004) |
Relevant generic standard(s)
Note 2.3
|
01.02.2008
|
|
|
|
|
CENELEC |
EN 61000-6-1:2001
Electromagnetic compatibility (EMC) --
Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
(IEC 61000-6-1:1997 (Modified)) |
EN 50082-1:1997
Note 2.1
|
Date expired (01.07.2004)
|
|
|
|
|
CENELEC |
EN 61000-6-2:2001
Electromagnetic compatibility (EMC) --
Part 6-2: Generic standards - Immunity for industrial environments
(IEC 61000-6-2:1999 (Modified)) |
EN 61000-6-2:1999
Note 2.1
|
Date expired (01.07.2004)
|
|
|
|
|
CENELEC |
EN 61000-6-3:2001
Electromagnetic compatibility (EMC) --
Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
(CISPR/IEC 61000-6-3:1996 (Modified)) |
EN 50081-1:1992
Note 2.1
|
Date expired (01.07.2004)
|
|
Amendment A11:2004 to EN 61000-6-3:2001 |
Note 3 |
01.07.2007 |
|
|
|
|
CENELEC |
EN 61000-6-4:2001
Electromagnetic compatibility (EMC) --
Part 6-4: Generic standards - Emission standard for industrial environments
(IEC 61000-6-4:1997 (Modified)) |
EN 50081-2:1993
Note 2.1
|
Date expired (01.07.2004)
|
|
|
|
|
CENELEC |
EN 61008-1:1994
Electrical accessories - Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) --
Part 1: General rules
(IEC 61008-1:1990 + A1:1992 (Modified)) |
-
|
-
|
|
Amendment A2:1995 to EN 61008-1:1994
(IEC 61008-1:1990/A2:1995) |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.07.2000) |
|
Amendment A14:1998 to EN 61008-1:1994 |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.01.2001) |
|
|
|
|
CENELEC |
EN 61008-1:2004
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) --
Part 1: General rules
(IEC 61008-1:1996 + A1:2002 (Modified)) |
EN 61008-1:1994
and its amendments
Note 2.1
|
01.04.2009
|
|
|
|
|
CENELEC |
EN 61009-1:1994
Electrical accessories - Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) --
Part 1: General rules
(IEC 61009-1:1991 (Modified)) |
-
|
-
|
|
Amendment A1:1995 to EN 61009-1:1994
(IEC 61009-1:1991/A1:1995) |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.07.2000) |
|
Amendment A14:1998 to EN 61009-1:1994 |
Note 3 |
Date expired (01.01.2001) |
|
|
|
|
CENELEC |
EN 61009-1:2004
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) --
Part 1: General rules
(IEC 61009-1:1996 + A1:2002 (Modified)) |
EN 61009-1:1994
and its amendments
Note 2.1
|
01.04.2009
|
|
|
|
|
CENELEC |
EN 61036:1996
Alternating current static watt-hour meters for active energy (classes 1 and 2)
(IEC 61036:1996) |
EN 61036:1992
Note 2.1
|
Date expired (01.06.1997)
|
|
Amendment A1:2000 to EN 61036:1996
(IEC 61036:1996/A1:2000) |
Note 3 |
Date expired (01.06.2003 |
CENELEC |
EN 61037:1992
Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers
(IEC 61037:1990 (Modified)) |
NONE
|
-
|
|
Amendment A1:1996 to EN 61037:1992
(IEC 61037:1990/A1:1996) |
Note 3 |
Date expired (01.12.1996) |
|
Amendment A2:1998 to EN 61037:1992
(IEC 61037:1990/A2:1998) |
Note 3 |
Date expired (01.05.2001) |
|
|
|
|
CENELEC |
EN 61038:1992
Electricity metering - Tariff and load controls - Particular requirements for time switches
(IEC 61038:1990 (Modified)) |
NONE
|
-
|
|
Amendment A1:1996 to EN 61038:1992
(IEC 61038:1990/A1:1996) |
Note 3 |
Date expired (01.12.1996) |
|
Amendment A2:1998 to EN 61038:1992
(IEC 61038:1990/A2:1998) |
Note 3 |
Date expired (01.05.2001) |
|
|
|
|
CENELEC |
EN 61131-2:1994
Programmable controllers --
Part 2: Equipment requirements and tests
(IEC 61131-2:1992) |
Relevant generic standard(s)
Note 2.3
|
Date expired (15.03.1995)
|
|
Amendment A11:1996 to EN 61131-2:1994 |
Note 3 |
Date expired (01.12.1996) |
|
Amendment A12:2000 to EN 61131-2:1994 |
Note 3 |
Date expired (01.01.2003) |
|
|
|
|
CENELEC |
EN 61131-2:2003
Programmable controllers --
Part 2: Equipment requirements and tests
(IEC 61131-2:2003) |
EN 61131-2:1994
and its amendments
Note 2.1
|
01.05.2006
|
|
|
|
|
CENELEC |
EN 61204-3:2000
Low voltage power supplies, d.c. output --
Part 3: Electromagnetic compatibility (EMC)
(IEC 61204-3:2000) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.11.2003)
|
|
|
|
|
CENELEC |
EN 61268:1996
Alternating current static var-hour meters for reactive energy (classes 2 and 3)
(IEC 61268:1995) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.07.1996)
|
|
|
|
|
CENELEC |
EN 61326:1997
Electrical equipment for measurement, control and laboratory use - EMC requirements
(IEC 61326:1997) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.07.2001)
|
|
Amendment A1:1998 to EN 61326:1997
(IEC 61326:1997/A1:1998) |
Note 3 |
Date expired (01.07.2001) |
|
Amendment A2:2001 to EN 61326:1997
(IEC 61326:1997/A2:2000) |
Note 3 |
Date expired (01.04.2004) |
|
Amendment A3:2003 to EN 61326:1997 |
Note 3 |
01.10.2006 |
|
|
|
|
CENELEC |
EN 61543:1995
Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility
(IEC 61543:1995) |
Relevant generic standard(s)
Note 2.3
|
Date expired (04.07.1998)
|
|
Amendment A11:2003 to EN 61543:1995 |
Note 3 |
01.03.2007 |
|
|
|
|
CENELEC |
EN 61547:1995
Equipment for general lighting purposes - EMC immunity requirements
(IEC 61547:1995) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.07.1996)
|
|
Amendment A1:2000 to EN 61547:1995
(IEC 61547:1995/A1:2000) |
Note 3 |
Date expired (01.11.2003) |
|
|
|
|
CENELEC |
EN 61800-3:1996
Adjustable speed electrical power drive systems --
Part 3: EMC product standard including specific test methods
(IEC 61800-3:1996) |
Relevant generic standard(s)
Note 2.3
|
Date expired (01.04.1997)
|
|
Amendment A11:2000 to EN 61800-3:1996 |
Note 3 |
Date expired (01.01.2002) |
|
|
|
|
CENELEC |
EN 61800-3:2004
Adjustable speed electrical power drive systems --
Part 3: EMC requirements and specific test methods
(IEC 61800-3:2004) |
EN 61800-3:1996
and its amendment
Note 2.1
|
01.10.2007
|
|
|
|
|
CENELEC |
EN 61812-1:1996
Specified time relays for industrial use --
Part 1: Requirements and tests
(IEC 61812-1:1996) |
-
|
-
|
|
Amendment A11:1999 to EN 61812-1:1996 |
Relevant generic standard(s)
Note 2.3 |
Date expired (01.01.2002) |
|
|
|
|
CENELEC |
EN 62052-11:2003
Electricity metering equipment (AC) - General requirements, tests and test conditions --
Part 11: Metering equipment
(IEC 62052-11:2003)
Note 9 |
Relevant generic standard(s)
Note 2.3
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 62052-21:2004
Electricity metering equipment (a.c.) - General requirements, tests and test conditions --
Part 21: Tariff and load control equipment
(IEC 62052-21:2004)
Note 11 |
EN 61037:1992
and its amendments + EN 61038:1992
and its amendments
Note 2.1
|
01.07.2007
|
|
|
|
|
CENELEC |
EN 62053-11:2003
Electricity metering equipment (a.c.) - Particular requirements --
Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2)
(IEC 62053-11:2003) |
EN 60521:1995
Note 2.1
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 62053-21:2003
Electricity metering equipment (a.c.) - Particular requirements --
Part 21: Static meters for active energy (classes 1 and 2)
(IEC 62053-21:2003) |
EN 61036:1996
and its amendment
Note 2.1
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 62053-22:2003
Electricity metering equipment (a.c.) - Particular requirements --
Part 22: Static meters for active energy (classes 0,2 S and 0,5 S)
(IEC 62053-22:2003) |
EN 60687:1992
Note 2.1
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 62053-23:2003
Electricity metering equipment (a.c.) - Particular requirements --
Part 23: Static meters for reactive energy (classes 2 and 3)
(IEC 62053-23:2003) |
EN 61268:1996
Note 2.1
|
01.03.2006
|
|
|
|
|
CENELEC |
EN 62054-11:2004
Electricity metering (a.c.) - Tariff and load control --
Part 11: Particular requirements for electronic ripple control receivers
(IEC 62054-11:2004) |
EN 61037:1992
and its amendments
Note 2.1
|
01.07.2007
|
|
|
|
|
CENELEC |
EN 62054-21:2004
Electricity metering (a.c.) - Tariff and load control --
Part 21: Particular requirements for time switches
(IEC 62054-21:2004) |
EN 61038:1992
and its amendments
Note 2.1
|
01.07.2007
|
|
|
|
|
CEN |
EN 617:2001
Continuous handling equipment and systems - Safety and EMC requirements for the equipment for the storage of bulk materials in silos, bunkers, bins and hoppers |
! |
|
CEN |
EN 618:2002
Continuous handling equipment and systems - Safety and EMC requirements for equipment for mechanical handling of bulk materials except fixed belt conveyors |
! |
|
CEN |
EN 619:2002
Continuous handling equipment and systems - Safety and EMC requirements for equipment for mechanical handling of unit loads |
! |
|
CEN |
EN 620:2002
Continuous handling equipment and systems - Safety and EMC requirements for fixed belt conveyors for bulk materials |
! |
|
CEN |
EN 12015:1998
Electromagnetic compatibility - Product family standard for lifts, escalators and passenger conveyors - Emission |
! |
|
CEN |
EN 12015:2004
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission |
EN 12015:1998 |
30.6.2006 |
CEN |
EN 12016:1998
Electromagnetic compatibility - Product family standard for lifts, escalators and passenger conveyors - Immunity |
__ |
|
CEN |
EN 12016:2004
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity |
EN 12016:1998 |
30.6.2006 |
CEN |
EN 12895:2000
Industrial trucks - Electromagnetic compatibility |
! |
|
CEN |
EN 13241-1:2003
Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics |
! |
|
CEN |
EN 13309:2000
Construction machinery - Electromagnetic compatibility of machines with internal electrical power supply |
! |
|
CEN |
EN 14010:2003
Safety of machinery - Equipment for power driven parking of motor vehicles - Safety and EMC requirements for design, manufacturing, erection and commissioning stages |
! |
|
CEN |
EN ISO 14982:1998
Agricultural and forestry machines - Electromagnetic compatibility - Test methods and acceptance criteria (ISO 14982:1998) |
! |
|
ETSI |
EN 300 386 V1.2.1
Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements |
EN 300 386-2 V1.1.3 |
31.08.2005 |
ETSI |
EN 300 386 V1.3.1
Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements |
EN 300 386 V.1.2.1 |
31.08.2005 |
ETSI |
EN 300 386 V1.3.2
Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements |
EN 300 386 V.1.2.1 |
31.08.2005 |
ETSI |
EN 300 386 V1.3.3
Electromagnetic compatibility and radio spectrum matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements |
EN 300 386 V1.3.2 |
31.01.2006 |
ETSI |
EN 300 386-2 V1.1.3
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; Electromagnetic compatibility (EMC) requirements; Part 2: Product family standard |
|
31.08.2005 |
General remark: when there is a stroke in the column 3 (reference of the superseded standard), it means that the referenced standard may not be used without amendment or particular part for EMC purpose.
Note 1: Generally the date of cessation of presumption of conformity will be the date of withdrawal ("dow"), set by the European standards body, but attention of users of these standards is drawn to the fact that in certain exceptional cases this can be otherwise.
Note 2.1: The new (or amended) standard has the same scope as the superseded standard. On the date stated, the superseded standard ceases to give presumption of conformity with the essential requirements of the directive.
Note 2.2: The new standard has a broader scope than the superseded standard. On the date stated the superseded standard ceases to give presumption of conformity with the essential requirements of the directive.
Note 2.3: The new standard has a narrower scope than the superseded standard. On the date stated the (partially) superseded standard ceases to give presumption of conformity with the essential requirements of the directive for those products that fall within the scope of the new standard. Presumption of conformity with the essential requirements of the directive for products that still fall within the scope of the (partially) superseded standard, but that do not fall within the scope of the new standard, is unaffected.
Note 3: In case of amendments, the referenced standard is EN CCCCC:YY, its previous amendments, if any, and the new, quoted amendment. The superseded standard (column 3) therefore consists of EN CCCCC:YY and its previous amendments, if any, but without the new quoted amendment. On the date stated, the superseded standard ceases to give presumption of conformity with the essential requirements of the directive.
Note 6: EN 60947-1:1999 does not give presumption of conformity without another part of the standard. EN 60947-1:2004 does not give presumption of conformity without another part of the standard.
Note 7: EN 60730-1:2000 does not give presumption of conformity without another part of the standard.
Note 8: EN 55012 is applicable for giving presumption of conformity under directive 89/336/EEC for those vehicles, boats and internal combustion engine-driven devices that are not within the scope of directives 95/54/EC, 97/24/EC, 2000/2/EC or 2004/104/EC.
Note 9: EN 62052-11:2003 does not give presumption of conformity without a part of the EN 62053 series.
Note 10: EN 60730-2-5:2002 does not give presumption of conformity without its amendment A1:2004.
Note 11: EN 62052-21:2004 does not give presumption of conformity without a part of the EN 62054 series.
This list (published in OJ C 246 of 2005-10-05) replaces all the previous lists published in the Official Journal of the European Union.